FX5U is equipped with analog functions, communication and high-speed I/O, and can easily be expanded with expansion boards and adapters.
The high-speed system bus communication brings out the maximum performance of expansion devices equipped with intelligent functions.
Control scale
|
32 to 384 points (CPU module: 32/64/80 points)
|
Max. 512 pts including CC-Link, AnyWireASLINK, and Bitty series remote I/O
|
Program memory
|
128 k steps (Comment and statements in separate area)
|
Built-in analog input/output
|
A/D 2 ch 12-bit
|
D/A 1 ch 12-bit
|
Built-in SD Memory Card Slot
|
Max. 16 GB (SD/SDHC memory card)
|
[Application]
|
Stores device comment file and folders/files created by functions using SD memory card.
|
Built-in Ethernet Port
|
10BASE-T/100BASE-TX
|
[Application]
|
-
Socket communication (Direct connection to other PLCs)
|
-
Remote maintenance (Read/write program with GX Works3 connected via VPN)
|
-
SLMP Communication (Read/write PLC device data from PC)
|
Built-in RS-485 port
|
Conforming to RS-485 and RS-422 standards
|
[Application]
|
-
Inverter Communication (Max. length 50 m, max. 16 units can be connected)
|
-
MODBUS® Communication (Up to 32 devices can be connected, including other PLCs, sensors, temperature controllers)
|
Built-in
|
Built-in positioning
|
4 axes 200 kHz pulse output
|
input/output
|
function
|
Built-in
|
Max. 8 ch 200 kHz high speed pulse input
|
|
high-speed counter
|
(FX5U-32M: 6 ch 200 kHz + 2 ch 10 kHz)
|
SIMPLE MOTION MODULES
Motion Module (CC-Link IE TSN)
Model
|
Number of
control axes
|
Main functions/Control
|
Compatible CPU module
|
FX5U
|
FX5UC
|
FX5UJ
|
|
FX5-40SSC-G
|
4 axes
|
Function
·Linear interpolation
·Circular interpolation
·Continuous trajectory
control
·S-curve acceleration/deceleration
Control
·Synchronous control
·Cam control
·Torque control
|
*1
o
Up to
4 modules
|
*1*2
o
Up to
4 modules
|
×
|
|
FX5-80SSC-G
|
8 axes
|
Function
·Linear interpolation
·Circular interpolation
·Continuous trajectory control
·S-curve acceleration/deceleration
Control
·Synchronous control
·Cam control
·Torque control
|
*1
o
Up to
4 modules
|
*1*2
o
Up to
4 modules
|
×
|
-
: Up to four modules of FX5-40SSC-G, FX5-80SSC-G and FX5-CCLGN-MS (master station) in total connectable per system.
Cannot be used together with FX5-SF-MU4T5 or FX5-SF-8DI4.
-
:When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
Simple Motion Module (SSCNET III/H)
Model
|
Number of control axes
|
Main functions/Control
|
Compatible CPU module
|
FX5U
|
FX5UC
|
FX5UJ
|
|
FX5-40SSC-S
|
4 axes
|
Function
·Linear interpolation
·Circular interpolation
·Continuous trajectory control
·S-curve acceleration/deceleration
Control
·Synchronous control
·Cam control
·Torque control
|
*1
o
Up to
16 modules
|
*2
o
Up to
15 modules
|
*3
o
Up to
1 module
|
|
FX5-80SSC-S
|
8 axes
|
Function
·Linear interpolation
·Circular interpolation
·Continuous trajectory control
·S-curve acceleration/deceleration
Control
·Synchronous control
·Cam control
·Torque control
|
*1
o
Up to
16 modules
|
*2
o
Up to
15 modules
|
*3
o
Up to
1 module
|
-
: For FX5U (DC power supply type), a powered I/O module is required and up to 15 modules can be connected.
-
: When connecting to FX5UC CPU, FX5-CNV-IFC or FX5-C1PS-5V and a powered I/O module are required, up to 15 modules can be connected.
-
: FX5-40SSC-S and FX5-80SSC-S cannot be used together.
High-speed pulse input/output module
Model
|
Number of control axes
|
Maximum frequency
|
Compatible CPU module
|
FX5U
|
FX5UC
|
FX5UJ
|
|
FX5-16ET/ES-H
|
2 axes
|
200 kpps
|
*1
o
Up to 4 modules
|
*1 *2
o
Up to 4 modules
|
×
|
FX5-16ET/ESS-H
|
-
: Supported in version 1.030 or later.
-
: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
Model
|
Number of control axes
|
Maximum frequency
|
Compatible CPU module
|
FX5U
|
FX5UC
|
FX5UJ
|
|
FX5-20PG-P
|
2 axes
|
200 kpps
|
o
|
*1
o
|
o
|
|
FX5-20PG-D
|
2 axes
|
5 Mpps
|
o
|
*1
o
|
o
|
|
FX3U-1PG
|
1 axis
|
200 kpps
|
*2
o
Max.
6 to 8 modules
*3
|
*2
o
Max.
6 modules
|
×
|
-
: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.
-
: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
-
: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.
FX5U/FX5UC/FX5UJ CPU module built-in output functions (Built-in positioning function)
Model
|
Generic Specifications
|
Function
|
|
FX5U CPU module
|
Max. 200 kHz 4 axes
*Supported by transistor output type CPU module
|
·JOG operation (Supported by variable speed operation)
·Machine home position return
·Fast home position return control
·1-speed positioning
·2-speed positioning
·Multi-speed operation
·Interrupt stop
·Interrupt and 1-speed positioning
·Interrupt and 2-speed positioning
·Variable speed operation
·Simple linear interpolation (Start 2-Axis simultaneously)
·Table operation
·Absolute position detection system
|
|
FX5UC CPU module
|
|
FX5UJ CPU module
|
Max. 200 kHz 3 axes
*Supported by transistor output type CPU module
|
|
|
|